Home › Guides › Water treatment components
Flow Meters for RO and Water Plants: Types, How to Read Them and Why They Matter

- Rotameters for RO lines
- Read at the float mark
- Recovery = permeate ÷ feed
- Log readings daily
On this page
Why Flow Meters Matter
An RO plant's output, membrane life and water quality depend on flows staying in the designed range. Without meters you cannot tell whether a membrane is fouling, a pump is weakening or someone has changed the reject valve. A few inexpensive meters prevent costly membrane replacements.
Instruments at H-TECH
Flow Meters panel mountedKSh 2,900
TDS Handheld MeterKSh 6,500
Conductivity Monitor – Model: CCT3320V (CM230)KSh 12,000
Conductivity ProbeKSh 3,000
Panel Mount RO Controller (RO-2015)KSh 15,000
Pressure SwitchKSh 4,500| Product | Price |
|---|---|
| Flow Meters panel mounted | KSh 2,900 |
| TDS Handheld Meter | KSh 6,500 |
| Conductivity Monitor – Model: CCT3320V (CM230) | KSh 12,000 |
| Conductivity Probe | KSh 3,000 |
| Panel Mount RO Controller (RO-2015) | KSh 15,000 |
| Pressure Switch | KSh 4,500 |
Current listed prices incl. VAT (updated 19 October 2026).
Types of Flow Meters
| Type | How it works | Use |
|---|---|---|
| Panel rotameter (variable area) | A float rises in a tapered tube | RO permeate and reject lines; no power needed |
| Paddle / turbine digital | Rotor speed measured electronically | Totalising, dosing control |
| Water meter (totaliser) | Counts total volume | Billing, daily production (see prepaid meters) |
How to Read a Rotameter
- Check the units on the scale (LPH, GPM).
- Read where the float's reading edge (as marked by the maker, often the top or the widest part) lines up with the scale.
- Read at eye level to avoid error.
- Note the reading when the plant is at normal operating pressure.
Calculating RO Recovery
| Permeate | Reject | Feed | Recovery |
|---|---|---|---|
| 250 LPH | 500 LPH | 750 LPH | 33% |
| 500 LPH | 500 LPH | 1,000 LPH | 50% |
Illustrative numbers. Run at the recovery the system designer specifies for your water; pushing recovery too high scales and fouls membranes.
What Changing Flows Tell You
- Permeate dropping at the same pressure: fouling or scaling; plan cleaning (RO maintenance).
- Reject rising, permeate falling: check the reject valve setting and membrane condition.
- All flows low: pre-filters blocked or pump problem; check the cartridges (sediment filter guide).
Installation Tips
- Mount rotameters vertically, flow from bottom to top.
- Choose a range so normal flow reads in the middle of the scale.
- Keep glass or acrylic tubes out of direct sun and clean them so the float is visible.
- Log permeate, reject, pressures and TDS daily.
Watch: RO purifiers and water ATMs
Frequently asked questions
What is a flow meter used for in an RO plant?
To measure permeate and reject flow so you can check output and recovery.
How do I read a rotameter?
Read the scale where the float's marked reading edge lines up, at eye level.
How do I calculate RO recovery?
Recovery = permeate flow ÷ (permeate + reject flow).
Why is my RO permeate flow dropping?
Usually membrane fouling or scaling, blocked pre-filters or low pressure.
Do panel flow meters need electricity?
No, rotameters work mechanically.